Xantrex Technology HF 1000 Battery Charger User Manual


 
Operating in Inverter Mode
975-0390-01-01 4–5
Status LED During Inverter Mode
The following summarizes the behavior of the Status LED during Inverter
mode.
Checking Battery Status
During inverter mode, you can check the battery status by pressing the
Select button until the Input Voltage LED (or Input Current LED)
illuminates. The battery voltage (or battery current) appears in the three-
digit LED display screen when the Input Voltage LED (or Input Current
LED) illuminates.
The normal operating battery voltage range is between 11 and 15 volts.
Table 4-1
Status LED during Inverter Mode
Status LED Display Screen Condition
Solid
YELLOW
12.8
(where 12.8 is an
example of battery
voltage)
Select button is pressed to display Input Battery Voltage.
The Input Battery Voltage LED lights up.
Value in display screen is shown as Volts.
11
(where 11 is an
example of current)
Select button is pressed to display Input Current.
The Input Current LED lights up.
Value in display screen is shown as Amps.
0.85
(where 0.85 is an
example of output
power in Kilowatts)
Select button is pressed to display Output Power.
The Output Power LED lights up.
Value in display screen is shown as Kilowatts.
E05 through e07
Warning condition detected while AC output power is still
available.
See Table 5-1, “Error Codes Displayed on the Display Panel
Screen” on page 5–5.
Solid RED
E01 through e04
Fault condition detected and AC output power is not
available. The unit will sound an alarm and will shutdown
completely within 30 seconds.
See Table 5-1, “Error Codes Displayed on the Display Panel
Screen” on page 5–5.
Off Off Inverter is OFF.
Off (or Yellow)
00.0
No communication between the Freedom HF and the Display
Panel because the battery voltage was too low to start the
Inverter.
Freedom HF Owners Guide.book Page 5 Friday, December 21, 2007 2:18 PM