Xantrex Technology IP1012 AL Battery Charger User Manual


 
Inverter Specifications
975-0337-01-01 A–3
Inverter Specifications
All inverter specifications are at nominal conditions; 1000 W resistive
load, 12 Vdc inverting on the IP1012 AL, 120 Vac, unless otherwise
specified.
Inverter specifications
Output wave form Modified sine wave
Output power continuous 1000 Vac continuous
Surge rating 3000 VA for 30 seconds at –40 °F to 77 °F
(–40 °C to 25 °C)
See Figure A-1 for output at different
temperatures.
Operating voltage range 10.4 Vdc to 16.0 Vdc
Input DC voltage rating 12 Vdc
Output voltage 120 Vac RMS
Output voltage regulation 108 to 125 Vac under steady state 0 to 1000 W
load with 10.6 to 14.5 Vdc input at 25 °C
(77 °F)
108 to 132 Vac up to 1000 W, 10.6 to 16 Vdc
input at – 40 °F to 185 °F (–40 °C to 85 °C)
Output frequency 60.0 ± 0.1 Hz from – 40 °F to 185 °F (– 40 °C to
85 °C) ambient temperature
Power factor allowed All (0 to 1, leading or lagging)
Peak efficiency Greater than 93% at 12.6 Vdc input at 77 °F
(25 °C)
Idle power consumption Less than 15 W (inverting with 120 Vac output
and no load)
Auto-shutdown mode Inverter output is less than 15 ±5 W and battery
is less than 13 Vdc for 8 hours
Off mode power
consumption
Less than 120 mW when inverter switch is off or
in auto off mode
IP1012_AL.book Page 3 Tuesday, May 1, 2007 12:18 PM