Xantrex Technology IP1012 AL Battery Charger User Manual


 
Transfer and General Specifications
975-0337-01-01 A–5
Transfer and General Specifications
Absorption charge voltage 14.3 ± 0.3 Vdc at 77 °F (25 °C)
Float charge voltage 13.3 ± 0.3 Vdc at 77 °F (25 °C)
Temperature compensation – 0.023 Vdc
from -2 °C to 85 °C (28.4 °F to 185 °F).
Below -2 °C, the charger voltage defaults to the –
2 °C voltage
Overvoltage shutdown Greater than or equal to 15.3 ± 0.3 Vdc
Transfer and general specifications
AC input/bypass current 15 AAC maximum continuous at 122 °F
(50 °C)
Derates to 5 AAC at 185 °F (85 °C)
Transfer speed 10–40 ms typical
AC low voltage transfer 90 ± 5 Vac
AC low voltage restart 95 ± 5 Vac, 30 second delay
AC high voltage transfer None
Standby/off consumption < 0.7 watts at 12.5 Vdc with charger and
inverter both off
Operating temperature range – 40 °F to +185 °F (– 40 °C to +85 °C)
Storage temperature range – 40 °F to +185 °F (– 40 °C to +85 °C)
Altitude limit 15 000 feet (5000 metres)
AC neutral to ground bonding Invert mode: AC output neutral is connected
to AC ground (chassis).
Charge mode: AC output neutral is connected
to AC input neutral.
AC input neutral is always isolated from AC
ground.
Charger specifications (Continued)
IP1012_AL.book Page 5 Tuesday, May 1, 2007 12:18 PM