Table A-1
Inverter Specifications
Output wave form Sine wave
Total harmonic voltage distortion <3%
Output power continuous 3000 W/3000 VA continuous
Surge rating 7500 W/7500 VA for 5 seconds
AC output voltage 120 VAC ± 5%
Input DC voltage rating 12 VDC nominal, 10 to 16 VDC
AC output frequency 60.0 ± 0.05 Hz
Power factor (lag or lead) 0 to 1.0
Peak efficiency >89%
Efficiency at 3000W >85%
No load power draw Load sense On <14W
Load sense Off <60W
DC low voltage shutdown 10 volts
DC over voltage shutdown 16 volts