Xantrex Technology RS3000 Battery Charger User Manual


 
Operation
975-0170-01-01 2–17
To enter or exit Power Save mode:
Press and hold the System button on the System Control Panel for one
second.
After you release the System button, the System Control Panel screen
and indicator lights will turn off.
You can also enter or exit Power Save mode on the System Settings
menu by selecting Desired Mode and scrolling to PowerSave as
shown in Figure 2-5.
Returning to
Operating mode
If an inverter/charger supplies power to the network, applying AC input
with utility power or generator power automatically returns the system to
Operating mode.
Safe Mode
Characteristics Selecting Safe mode stops the generator (if it is running) and puts the
System Control Panel (and all Xanbus-enabled devices) into Safe mode.
While in Safe mode, the System Control Panel remains powered,
“listening” to and reporting its status to the network. However, the ouptut
power of all Xanbus-enabled devices is disabled and all inverting,
charging, and generator starting activity stops. In Safe mode, the RS3000
will not transfer AC power from a source.
Figure 2-5
Power Save Mode
Operating
[Advanced]
CAUTION: Unexpected behavior
Before installing or removing a device on the network, put the network into Safe
mode. This prevents unexpected behavior.