Xantrex Technology XC5012 Battery Charger User Manual


 
Troubleshooting
4–4 975-0187-01-01
Error Messages on Remote Display
Table 4-2
Error Messages
Display
Onboard Status Panel
Indicator lights Fault Solution
Red fault indicator light
flashing or illuminated
Fault A fault has been detected. The fault code
will be shown immediately after
.
AC Low
Warning
Check AC connections, check AC
availability at source.
Red fault indicator light
illuminated
Reverse
Polarity
Reverse Polarity Battery connected.
Check connections. Ensure correct
polarity (negative connected to negative,
positive connected to positive).
Red fault indicator light
flashing
Charger
Hardware
Fault
Call for service.
Over-
temperature
Warning
Allow the XC Series to cool. Improve
ventilation or install in cooler location. If
the temperature increases, the XC Series
will enter the fault level and stop
functioning.
Red fault indicator light
illuminated
Over-
temperature
Shutdown
Allow the XC Series to cool. Improve
ventilation or install in cooler location.
Green 10% indicator light
flashes
Display green bank indicator
light for affected battery bank
illuminated
Battery Too
Cold Warning
Allow batteries to warm up before
attempting to charge again. Charging a
battery that has frozen is a potential
explosion hazard. If the temperature
drops, the XC Series will enter the fault
level and stop charging the affected bank.
XC_Charger_Owner.book Page 4 Friday, August 12, 2005 3:23 PM