A SERVICE OF

logo

SKU 92504 For technical questions, please call 1-800-444-3353. Page 8
outlet that is properly grounded.
To Attach Quick Connectors:
Prior to use, the Air Compressor requires the attachment of a 1/4” NPT Quick
Connector (not included) to each of its two Air Outlet Valves (4). To do so, wrap
approximately 4” of pipe thread sealant tape (not included) around the male threads
of the Quick Connectors. Then, firmly screw the Quick Connectors into the Air Outlet
Valves. (See Figure D.)
To Fill The Air Compressor With Oil:
1. CAUTION! Prior to its first use, and thereafter prior to each subsequent
use, make sure to fill the Air Compressor with a premium quality, 30 weight,
non-detergent oil. Running the Air Compressor with no oil or low oil will cause
damage to the equipment and void its warranty.
2. When filling the Air Compressor with oil, make sure to unscrew (do not pull) the Oil
Fill Cap (28) to remove. (See Figure D.)
AIR
OUTLET VALVE
(4)
AIR
OUTLET VALVE
(4)
FIGURE D
OIL FILL CAP
(28)
OIL LEVEL
INDICATOR
(35)