Installation and commissioning
8 - 8
● Switch the machine on at the main switch and tilt it back.
The error message "E9" must appear on the control panel.
● If the message does not appear, check the setting of switch
4
.
● Set the sewing head upright and acknowledge the error message by pressing the
TE/
Speed
key. The machine is ready for operation again.
E9
ERROR
8.08 Mounting/connecting the start inhibitor
(only on machines with Quick-flange motor)
● For machines delivered without a table, the plate
1
from the accessories should be
mounted under the table top, so that the switch lug
2
is resting on plate
1
when the
sewing head is in an upright position.
● Loosen screws
3
and adjust switch
4
so that the switch lug
2
is free when the sewing
head is tilted back and pressed when the sewing head is upright.
● Connect plugs
5
and
6
to the switch
4
.
Function check of the start inhibitor
Fig. 8 - 09
2
4
3
92-015
1
5
6