12 - 34
12.06.02 Knife height
Requirement
When the adjustment lever
1
is set at "0" and the knife is at the top of its stroke, the top
edges of the needle plate and knife should be at the same level.
Set adjustment lever
1
at "0".
Remove cover cap
2
and turn the motor impeller wheel until the knife is positioned at its
t.d.c.
Adjust linkage rod
3
(screw
4
) in accordance with the requirement.
Fig. 12 - 33
2
3
1
4