119
A
l00 Vac Input Power Option 100
General Information
Description
Option 100 is a modification of Agilent 6030A/31A/32A/35A power supplies that involves changing resistors on the A2
board, recalibrating the supply, and changing the Front Panel. These changes allow the units to operate at a lower line
voltage of 87 to 106 Vac, while operating on the same line frequency of 48 to 63 Hz. The reduced input voltage limits the
output power to approximately 700 watts. Other specifications that change due to Option 100 include Programming
Response Time, Overvoltage Protection and Remote Analog Programming.
Scope of Appendix A
This appendix contains all the information necessary to support Agilent 6033A/31A/32A/35A power supplies that are
equipped with Option 100. The appendix describes only the changes pertaining to Option 100 and how they affect the other
portions of this manual. Unless otherwise specified in Appendix A, all other portions of the annual apply to both the
standard unit and the Option 100 unit.
Suggestions for Using Appendix A
The Option 100 changes are listed sequentially, starting with Chapter 1 in the main body of the manual and working back
through Chapter 6. It is recommended that the user mark all the necessary changes directly into his manual. This will update
the manual for Option 100 and eliminate the need for constant referrals back to Appendix A.
Chapter 1 Manual Changes
On Page 9, in Scope change the output power from 1000 to 700 watts.
Chapter 2 Manual Changes
On Page 17, in Constant Voltage Full Scale Calibration step b, and Voltage Monitor and Remote Readback Full Scale
Calibration step b, change the VSET values to:
VSET 170 (6030A)
VSET 50 (6032A)
VSET 425 (6035A)