Anderson Manufacturing 8000 602 050 Rev. B Welding System User Manual


 
- 11 -
6.1.3. Admin Parameters
CXR - SeriaLAN
Admin Parameters Menu
1) IP Address : 192.168.1.1
2) Netmask : 255.255.255.0
3) Gateway : 192.168.1.254
4) TelnetD : valid
5) FTPD : valid
6) Bootp : invalid
-------------------------------------------------------------------------
Type your choice: 1 .. 6, P(revious) and press RETURN
-------------------------------------------------------------------------
Enter and validate the number of the parameter to change (‘1’ and Enter for example).
Enter the literal value of the parameters 1, 2 and 3. Then validate the parameter with the
Enter key.
IP Address :
Configure the IP address of the unit. This parameter is used only to manage the unit from
the LAN or from the remote network. In other cases, it should be left at 0.0.0.0
Netmask :
Set the network mask to comply with the network IP address map.
Gateway :
Enter the address of the default gateway (router) that gives access to the unit from a
remote network. Leave this parameter at 0.0.0.0 if no router is used.
TelnetD:
This parameter enables the management of the unit through Telnet sessions (TCP port 23).
SeriaLAN can serve up to 5 simultaneous sessions.
FTPD:
This parameter enables updates of the internal code (firmware) through FTP protocol.
SeriaLAN is then an FTP server that serves connections from any user with the administrator
password. The firmware provided by CXR (*.LM file) should be sent to the unit in binary
mode as the file name : update.lm ( for example : put update.lm)