Barco R9855510 Work Light User Manual


 
2. System Overview
On the inside of the control panel there can be found:
2 x relay 12V/30A for guarding oil pressure and temperature of cooling liquid with aid of a stopping coil (Engine shuts off when
the oil pressure is low or the temperature of the cooling liquid is to high).
1 x relay 12V/30A by-pass guards (oil pressure) when starting engine.
2.5.4 Starting and using the generator
CAUTION: The generato r 183TDE is equipped with a 12V electric fuel p ump. This pump may not “run dry”. If
the engine stops because it is out of fuel, turn the contact key to position “OFF” as fast as possible.
Starting the engine
1. Check the oil level. Oil dipstick can be reached through the plastic cover on top of the generating set
Image 2-10
Oil level check
2. Check the fuel level, add if necessary .
Image 2-11
Fuel check
Caution: Adding fuel with engine stopped and in a sufficiently ventilated room, respecting the necessary personal sa fety pre-
cautions.
3. Preheat the engine for approximately 10 sec.
4. Start the engine with the starting key.
Image 2-12
5. Let the engine run for a few minutes before charging.
Charging the generator
1. On the type indication plate ofthe ge
nerator you can find more information about the power/maximum admissible charging current
of the generator.
R5976956 B-10 MOBILE LED 19/06/2007
17