4. Maintenance, Service
Daily 500 km
Quarterly
Yearly
C
L
T
Cl C
L
T
Cl C
L
T
Cl C
L
T
Cl
cylinder flexible
attachment to grid
Generator
general
motor
alternator
oil
gas - diesel
exhausts
fixing
state
C = Control
L = Lubricate
T = Tighten
Cl = Clean
After 50h 00 the d iesel g enerator need s to get its first mainten ance. Please refer to the Kubota and Leroy
Somer manuals as well as section 4.2 for more information on maintenance of the generator.
Used oil in the B-10 Mobile LED
Oil used in the generator is 10 W 40 for ambient temperature up to -20°C.
Hydraulic oil is SAE 35
4.2 Service and Maintenance of the Generator
Parts
The B-10 Mobile LED is equipped with a diesel-fueled generator. The generator is composed of a diesel motor from Kubota (KUB-
OTA D1105) and an alte
rnator from Leroy Somer (LSA 37M8).
Alternator
The alternators are maintenance-free. A periodic check of the alternator is not necessary. A regular visual control of the different
alternator parts – and especially of the rotor bearing – at every engine maintenance is enough.
Engine
Check engine manual for maintenance intervals.
Below you will find a list of official service centres for the Kubota and Leroy Somer components. Please refer to their respective
manual for more detail on these components and their maintenance.
CAUTION: The diesel generator needs after 50h00 its first maintenance run.
Remarks
In the factory, the radiator has been filled with coolant for use up to -15°C.
The engine has been filled in the factory with 10W40 oil (up to -20°C). If a lower temperature is needed, fill with 5W40 oil (up to
-30°C).