Step 2 – Using Your
HousePainter (Cont.)
roller with paint. When paint begins
to dot the roller cover (see Figure 19)
continue to hold the trigger and begin
rolling the wall . When the roller cover
is saturated, release the trigger and
continue rolling the surface. Only
depress the trigger when the roller
cover needs more paint.
The paint saved with this system is
approximately 1/3 of the amount a
manual roller uses. You also save time
and energy by eliminating the bend-
ing required when using a roller pan.
Refer to the roller instructions for
cleaning procedures.
Step 3 – Cleaning &
Storage
Cleaning the HousePainter is very sim-
ple. It is basically just following the
same procedure with water or solvent
that you have just done with the coat-
ing. To speed the process, place the
bypass tube in a waste bucket so you
do not contaminate the cleaning fluid.
Use whatever material the paint man-
ufacturer recommends for cleaning.
For overnight storage, submerge the
gun in a bucket of the appropriate
cleaning fluid (see Figure 20). Leave
the suction and bypass tubes in the
bucket of coating. Cover the tubes and
bucket with a damp towel, or if using
latex paint, pour a very thin layer of
water over top of paint. Stir water into
paint the next morning.
Coatings That Clean Up With Water.
When you are finished painting, turn
the One Touch Control knob to the
prime position (see Figure 14). Lift the
suction tube above the paint level and
allow any residual coating to flow into
the coating container from the bypass
tube. When there is little to no paint
coming out of the bypass tube, turn
the sprayer off.
Place the suction tube in a bucket of
warm water. If you use a waste bucket,
place the bypass tube in it. If not, the
bypass tube should also go into the
bucket of warm
water. Turn the One
Touch Control to
the clean pump
position (see Figure
21).
If using a waste
bucket, allow the
sprayer to run in this
mode until water is no longer coming
out of the bypass tube. If a waste
bucket is not being used, allow the
water to circulate for about 5 minutes.
Repeat this process at least once, or
until you see clear water coming out
of the bypass tube. Make sure to turn
the HousePainter off when
Figure 21 - Icon
showing Clean
Pump position
Figure 20– Submerge gun in bucket
of appropriate cleaning fluid