Chauvet DVM-HR Impact Driver User Manual


 
Setup
16:9 Aspect Ratio
8 meters by 4.5 meters
J7
J8
J9
J7
J8
J9
J7
J8
J9
Front View
Starting Address: 0
96 pixels wide or
96 vertical lines
Starting Address: 96
J1
J2
J3
J4
J5
J6
Driver 3 Driver 2
Driver 1
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 1 0 0 0 0 0 0 0 0 0
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
1 1 0 0 0 1 1 0 0 0 0 0
Driver 2
Width = 96
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
Start = 96
JP2
1 2 3 4 5 6 7 8 9 10 11 12
1 0 0 0 0 1 1 0 0 0 0 1
System Information
Vertical lines: 256
Horizontal lines: 144
Resolution: 256 x 144 pix
Size: 8m x 4.5m
Panels: 144 (16 x 9)
Power: 8 x 20A (110V)
Drivers: 3
Net Out: Out 1
J Ports: 1 ~ 9
J1
J2
J3
J4
J5
J6
J1
J2
J3
J4
J5
J6
96 pixels wide or
96 vertical lines
256 pixels wide or
256 vertical lines
64 pixels wide or
64 vertical lines
Starting Address: 192
Driver 1
Driver 3
Width = 96
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
Start = 0
JP2
1 2 3 4 5 6 7 8 9 10 11 12
0 0 0 0 0 1 1 0 0 0 0 0
16 meters by 9 meters
By now you should have a good understanding of the steps involved in configuring fairly simple sizes.
The following example will not illustrate the grid but will present all dipswitch settings in a table format
and relevant system information for a 16 by 9 meter matrix. J1~J8 are used for Net OUT2 only.
Driver
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 0 0 0 0 0 0 0 0 0
1
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
1 1 1 0 0 1 1 0 0 0 0 1
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
2
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
0 1 1 0 0 1 1 0 0 0 0 0
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
3
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
0 0 0 0 0 1 1 0 0 0 0 1
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
4
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
1 1 0 0 0 1 1 0 0 0 0 0
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
5
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
1 0 0 0 0 1 1 0 0 0 0 1
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
6
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
0 0 0 0 0 1 1 0 0 0 0 0
System Information
Vertical lines: 512 Power: 96 x 20A (110V)
Horizontal lines: 384 Drivers: 12
Resolution: 512 x 384 pix Net Out: Out1 & Out2
Size: 16m x 9m J Ports: Out1: J1 ~ J16
Panels: 768
(
32 x 24
)
J Ports: Out2: J1 ~ J8
Driver
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 0 0 0 0 0 0 0 0 0
7
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
1 1 1 0 0 1 1 0 0 0 0 1
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
8
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
0 1 1 0 0 1 1 0 0 0 0 0
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
9
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
0 0 0 0 0 1 1 0 0 0 0 1
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
10
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
1 1 0 0 0 1 1 0 0 0 0 0
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
11
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
1 0 0 0 0 1 1 0 0 0 0 1
Width = 64
JP1
1 2 3 4 5 6 7 8 9 10 11 12
0 1 0 1 0 0 0 0 0 0 0 0
12
Start = 192
JP2
1 2 3 4 5 6 7 8 9 10 11 12
0 0 0 0 0 1 1 0 0 0 0 0
DV Wall System User Manual 18 2007-02-05/16:45