Elektra Beckum Cool 401 Air Compressor User Manual


 
21
11.02
!
Part 5 Maintenance
5.1.4 Weekly maintenance
5.1.5 Cleaning of filter be-
fore condensate
drain with solenoid
valve
5.1.5.1 Dismounting of
filters
Fig. 17: Solenoid valve, ball
valve with filter
5.1.5.2 Mounting of Filters
5.1.6 Sensor controlled
condensate drain
(option)
Inspection and cleaning of condensate draining system
if necessary.
Attention!
Maintenance work must be performed at the depressu-
rized condensate trap only. For this purpose, the instal-
lation of a bypass line is recommended (additional
equipment).
a) disconnect CA-dryer from compressed air system
b) remove side wall (Fig. 5/9)
c) shut ball valve
d) depressurize by operating the condensate drain
key (Fig. 9/2).
e) remove cap
f) remove filter and clean with neutral cleaning agent,
replace if necessary.
Mounting is done in reverse order.
Replace working parts yearly (see spare parts list)
1 Ball valve with filter insert
2 Filter
3 O-ring
4 Cap
5 Solenoid valve
1
2
3
4
5