Elektra Beckum Cool 401 Air Compressor User Manual


 
24
11.02
Part 5 Maintenance
5.2.4.3 Sensor-controlled
condensate drain
5.2.4.3.1 Blocked discharge
pipe
5.2.4.3.2 Operation pressure
below required mini-
mum
Cause
5.2.4.4 Temporary overload of
the CA-dryer due to
non-uniform com-
pressed air consump-
tion
5.2.4.5 Overload due to high
volume flow, or too high
compressed air inlet
temperature
(with installed bypass line)
5.2.4.6 Bypass valve of bypass
line opened
5.2.4.7 Bypass valve of bypass
line leaky
Clean condensate drain with neutral cleaning agent.
Increase working pressure
Remedy
Reduce load, check whether CA-dryer´s capacity is prop-
erly selected
Reduce CA-consumption or increase CA-dryer´s capac-
ity
Close bypass valve in the bypass line
Seal or replace bypass valve in the bypass line,