Elektra Beckum Cool 401 Air Compressor User Manual


 
23
11.02
5.2.2 Acknowledgement of
failures
Fig. 21: Acknowledgement of
failures
5.2.3 Function:
Cause
No function
5.2.4 Water in compressed
air system
Cause
5.2.4.1 Condensate is not
drained properly
5.2.4.2 electronic regulated
condensate drain
5.2.4.2.1 Faulty condensate
draining
5.2.4.2.2 Solenoid valve de-
fective
Part 5 Maintenance
Remedy
- Check and establish power supply if necessary
- If the power supply is ok, call for service or send CA-
dryer to the manufacturer.
Remedy
- check condensate separator behind the compressor.
- possibly install automatic drain
- no sufficient drainage of the condensate separator
behind the compressor, extend condensate draining
time.
Clean solenoid valve
Replace solenoid valve
1. For acknowledgement operate
data selector key ( ) for 5
seconds.
2. Operate data selector key ( )
once more until P02 appears .
3. Acknowledgement of failure
through condensate drain
key ( )
4. For returning into display mode
press data selector key ( )
for 5 seconds.