Elektra Beckum Cool 401 Air Compressor User Manual


 
8
11.02
2.1 Transportation
2.2 Requirements on
the place of in-
stallation
2.3 Installation
(mounting)
Fig. 1: Installation of
CA-dryer
Part 2 Installation
Transportation has to be carried out in the normal oper-
ating position of the CA-dryer.
For a short time an inclined position of 45 ° is allowed.
At the site of installation, the CA-dryer can be installed
without anchorage or special foundation at the location
desired.
The CA-dryer is provided for an ambient temperature of
25 °C.
Attention!
To avoid corrosion at components of the CA-dryer the
compressed and ambient air must be free of aggressive
parts.
The CA-dryers are provided for inside mounting.
Deviating conditions require the consultation of the manu-
facturer.
To prevent the condensate from freezing the room tem-
perature must not drop below +2 °C.
Attention!
At different ambient conditions pay attention to the lay-
out data!
The CA-dryer must be installed that accessibility to the
front panel is ensured. Furthermore leave space for serv-
ice purpose on both sides of the CA-dryer (fig. 1).
Wall mounting is possible with all types.
!
!