Graco 3A2587H Paint Sprayer User Manual


 
Shutdown and Cleaning
3A2587H 15
Shutdown and Cleaning
The motor has a built-in feature to protect itself from
overuse. If the motor stops, the thermal switch has tripped. Do
not return sprayer to store. The motor will operate normally
after cooling for 20-30 minutes.
For best results, do not spray more than one cup of water
through the tip while cleaning. If more flushing is needed,
remove the tip from the sprayer.
Flushing Sprayer
1. Engage trigger lock and pull prime/spray valve UP to
release pressure.
2. Remove material cup and return excess material to
proper container. If used, properly dispose the material
cup liner.
3. Remove flexible suction tube as shown below.
4. Use screwdriver to pry flexible suction tube strainer from
flexible suction tube.
5. Clean flexible suction tube and suction tube strainer with
water (or flushing fluid) and a brush every time you flush
the sprayer. Reconnect flexible suction tube and suction
tube strainer and orient as shown.
6. Clean material cup if not using a liner, and fill with water or
appropriate flushing fluid.
7. Reconnect material cup and shake sprayer to move clean
water around and clean all areas inside of cup.
NOTICE
Failure to properly clean sprayer after each use will result in
hardened materials, damage to the sprayer, and the war-
ranty will no longer be valid. Do not store solvents other
than mineral spirits in sprayer. Always flush with Graco
Pump Armor prior to storage.
Use only water-based or mineral spirit-type materials
with flash point greater than 100° F (38° C). Do not use
materials which state “FLAMMABLE” on the packaging. For
more information about your material, request MSDS from
distributor or retailer.
Use oil-based material outdoors or in a well-ventilated indoor
area with a flow of fresh air.
Keep spray area well-ventilated. Keep a good supply of
fresh air moving through the area.
NOTICE
Protect the internal parts of this sprayer from water. Do
not submerge the sprayer in cleaning fluid. Openings in
shroud allow cooling of mechanical parts and electronics
inside. If water or cleaning fluid gets into these openings,
the sprayer could malfunction or become permanently dam-
aged.
i14994
ti18912a
ti16700a
NOTICE
When removing flexible suction tube from sprayer, make
sure to pull directly on top fitting of flexible suction tube. The
tube will become damaged if pulled from bottom or on flexi-
ble portion.
ti19034a
ti18952a
ti18859a
ti19035a
ti19463a
ti15017a
ti18920a