Graco XP70 Paint Sprayer User Manual


 
Prime Empty Sprayer
3A0420H 21
Prime Empty Sprayer
Prime A and B Fluids
NOTE: The equipment is tested with mineral oil at
the factory. If necessary, flush out the oil with a
compatible solvent before spraying. See Empty and
Flush Entire System (new sprayer or end of job),
page 27.
Do not install the gun spray tip yet. To avoid splash-
ing, use the lowest pressure possible to prime.
1. Condition the materials prior to adding to the hop-
pers (J). Ensure that the resin materials are thor-
oughly mixed, homogenous, and pourable prior to
adding to the hopper. Stir the hardeners back into
suspension prior to adding material to hopper.
2. Fill the A and B reservoirs with proper materials. Fill
the A side (blue) with major volume of material; fill
the B side (green) with minor volume of material
(unless 1:1 mix ratio).
3. Move the recirculation lines (U) to empty containers.
4. Close the dual shutoff handle (AE) and open the cir-
culation handle (AC).
5. Open the main air shutoff valve (CA).
6. Slowly open the air regulator (CB).
7. Dispense fluid in to the containers until clean fluid
comes out of the A and B recirculation lines.
8. Decrease air pressure. Close the main air shutoff
valve (CA).
9. Move the recirculation lines (U) back to the correct
hopper (J).
10. If using heaters, heat fluid throughout system before
spraying. See Recirculate or Re-Prime After a
Pump Runs Dry, page 23.
Wear gloves when using flush solvents and/or if the
fluid temperature exceeds 110°F (43°C).
J
U
AC
AE
r_571101_3A0420A_9a-2
CA