Graco Inc. 02748 Paint Sprayer User Manual


 
308-34111
Setup
and Shutdown
6. Adjust the spray pattern. (continued)
C. Hold
the gun parallel to the floor and adjust the
adhesive fluid pressure until you have a 1 to 6
inch (25.4 to 152.4 mm) straight fluid stream
before the stream falls of
f. See Fig. 14.
02754
1–6
in.
(25.4–152.4 mm)
straight fluid stream
Fig.
14
NOTE:
A larger fluid nozzle at a reduced adhesive
pressure will maintain the same flow rate, but slow
down the fluid stream. See Fig. 15. This allows the
atomizing air to act on the fluid longer and improve
the atomization.
Fluid Stream of Fluid Nozzles
at the Same Flow Rate
Fig. 15
02755
0.042
(1.067)
0.055
(1.397)
0.070
(1.778)
0.086
(2.184)
0.110
(2.794)
Nozzle
Orifice Size in inches (mm)
D. To
further reduce the volume of adhesive out
-
put at the gun, turn the fluid adjustment knob
(8) clockwise as needed. See Fig. 16. How
-
ever
, for the best results, adjust the adhesive
pressure or use a dif
ferent size needle/nozzle/
air cap combination to change the fluid flow
.
Refer to page 4.
CAUTION
Continuously spraying with the fluid adjustment knob
closed
,
will cause accelerated wear on the fluid
needle and trigger/air valve shaft interface.
If the fluid adjustment knob is fully closed, the gun
will emit only air and activator
.
Fig. 16
8
Close
02784
E.
Open the pattern adjusting valve by turning the
knob (13a) fully counterclockwise. See Fig. 17.
02784
Fig. 17
13a
Open
(wider
pattern)
Close
(narrower
pattern)