3. Connect the air supply to the tool at the Air Plug (82-not included). Set the regula-
tor at the recommended 70 to 125 operating PSI. Do not exceed the maximum
125 PSI.
4. Test the tool by depressing the Safety (38) against a piece of scrap wood without
pulling the Trigger (60). The tool must not cycle (fire). If it cycles (fires), stop
immediately and have it repaired by a qualified service technician.
(See Figure B.)
5. Hold the tool away or off the workpiece. The Safety (38) of the tool should return
to its original position. Squeeze the Trigger (60). The tool should not cycle
(fire). If the tool cycles (fires), stop immediately and have it repaired by a qualified
service technician. (See Figure B.)
6. Depress the Safety (38) against the workpiece and squeeze the Trigger (60). The
tool must cycle (fire) only once. Release the Trigger and squeeze it again. The
tool must not cycle (fire). With the Trigger held, carefully lift the Nailer and press
it against the scrap wood again. The tool must not cycle (fire). If it fails to
perform in the manner explained in bold, have it repaired by a qualified service
technician. (See Figure B.)
SKU 93257 For technical questions, please call 1-800-444-3353 PAGE 7
LATCH
(57)
DOOR
(32)
MAGAZINE COVER
(91)
FIGURE C
LOADING COIL NAILS
WARNING: Always wear ANSI approved impact safety goggles when
reloading or performing any other maintenance on this tool. Other people
in the work area must also wear ANSI approved impact safety goggles.
WARNING! Make sure the Nailer is not attached to the air hose when
loading the tool.
1. To open the Magazine Cover (91), press down on the Latch (57) and swing the
Door (32) open. Then, swing the Magazine Cover open. (See Figure C.)
Rev 11/06; REV 12/06