HP (Hewlett-Packard) 16500C Sander User Manual


 
LASTstate
Command :TGTctrl:LASTstate<N> <state>
The LASTstate command sets a signal’s last state. LASTstate has no effect
unless the signal type is sequence.
<N> An integer, 0 through 7, specifying signal.
<state> An integer, 1 through 7.
Example OUTPUT XXX;":TGTCTRL:LAST2 4"
Query :TGTctrl:LASTstate<N>?
The query returns the current last state. For toggle and pulse signals, the
last state is always 1.
Returned Format
[:TGTctrl:LASTstate<N>] <state><NL>
Example OUTPUT XXX;":TGTCTRL:LAST1?"
TGTctrl Subsystem
LASTstate
14–10