HP (Hewlett-Packard) ISCSI SR2122 Router User Manual


 
SR2122 Configuration Rules
11iSCSI SR2122 Storage Router: Getting Started Guide
SR2122 Configuration Rules
SR2122 Router Rules
The SR2122’s 2
nd
fibre Channel port (FC2) is not supported as a redundant SAN port for
FC1.
Direct connect of the SR2122 FC ports to any HP storage array is not supported.
The SR2122 Management port must be in a different subnet than the SCSI Router
Instances.
ISCSI Host Rules
Operating System Rules
Linux Clustering is not supported.
HP Secure Path for MSA1000, RA/MA8000, EMA/ESA12000 and Enterprise Virtual
Array for Linux are not supported.
HP Auto Path for VA/XP for Windows 2000 and Linux are not supported.
HP Secure Manager on XP and VA is not supported.
Microsoft Initiator Rules
Supported on Windows 2000 and Windows 2003 only
MSCS Clusters not supported
Table 1: SR2122 Router Rules
Maximum scsirouter instances per SR2122 Router (and per SR2122 Router
Cluster)
12
Maximum iSCSI host connections per SR2122 SCSI Router instance 32
Maximum active targets per SR2122 Router 100
Table 2: iSCSI Host Rules
Maximum targets accessed per iSCSI host Windows 2000, 2003 8
Red Hat Linux 16
Maximum LUNs per target Windows 2000, 2003 255
Red Hat Linux 256