HP (Hewlett-Packard) ISCSI SR2122 Router User Manual


 
Serving Fibre Channel Storage to the SR2122
22 iSCSI SR2122 Storage Router: Getting Started Guide
Presenting XP LUNs to the SR2122
XP storage volume must be pre-configured before the LUN(s) can be detected and recognized
by the SR2122. The XP can be configured either through the XP console (SVP) or Command
View XP.
Note: Although XP's HP Storage Works Secure Manager XP can configure XP LUNs to be selectively
presented for SR2122's FC port, it is not supported at this time. Hence, the entire LUNs configured
on the XP's Fibre channel port is presented to the SR2122. It is required to have this port dedicated
to the SR2122 fabric zone.
1. Set the Fibre Channel HOST MODE: 00 (to reflect Linux or Windows OS)
2. Select the FIBRE TOPOLOGY (depends on the configuration)
3. Updated SAN support is available via HP's internal web at
http://turbo.rose.hp.com/s pock
select "XP SAN Support Connectivity Streams" on the web page.
Note: No additional configuration is required for running SR2122 in cluster mode, since the other
SR2122's FC port is also on the same fabric zone and has the same access to the LUNs on the XP
array's Fibre channel port.
The SR2122 should now present the LUNs as storage to iSCSI initiator.