2- 5
2.4 Check of the warning monitor contents
Warning message is come out when there is any contradiction.
Program lamp “PRG” is turned ON while warning (until the data are corrected).
Warning message and automatic rewriting
Warning Related parameters
condit
ion
Base
001/ 201
Frequency upper limiter A061/A261 >
002/ 202
Frequency lower limiter A062/A262 >
004/ 204
Base frequency A003/A203 >
005/ 205
Output frequency F001, Multistage speed 0 A020/A220 >
006/ 206
Multistage speed 1-15 A021-A035 >
009
Orientation speed setting P015 >
Maximum
frequency A004/A204
012/ 212
Frequency lower limiter A062/A262 >
015/ 215
Output frequency F001, Multistage speed 0 A020/A220 >
016/ 216
Multistage speed 1-15 A021 - A035 >
Frequency upper limiter
A061/A261
021/ 221
Frequency upper limiter A061/A261 <
025/ 225
Output frequency F001 , Multi stage speed 0 A020/A220 <
Frequency lower limiter
A062/A262
031/ 231
Frequency upper limiter A061/A261 <
032/ 232
Frequency lower limiter A062/A262 <
035/ 235
Output frequency F001 , Multi stage speed 0 A020/A220 <
036
Multi stage speed 1-15 A021-A035 <
037
Jogging frequency A038 <
Start frequency b082
085/ 285
Output frequency F001 , Multi stage speed 0 A020/A220 <>
086
Multi stage speed 1-15 A021-A035 <>
Jump freq.
1/2/3 +/- Jump width
A063 +/ - A064
A065 +/- A066
A067 +/- A068 (note 1)
091/ 291
Frequency upper limiter A061/A261 >
092/ 292
Frequency lower limiter A062/A262 >
095/ 295
Output frequency F001 , Multi stage speed 0 A020/A220 >
096
Multi stage speed 1-15 A021-A035 >
Free v/f 7 b112
Free v/f frequency 1-6 b100,b102,b104,b106,b108,b110 > Free v/f 1 b100
Free v/f frequency 2-6 b102,b104,b106,b108,b110 <
Free v/f frequency 1 b100 >
Free v/f 1 b100
Free v/f 2 b102
Free v/f frequency 3-6 b104,b106,b108,b110 <
Free v/f frequency 1,2 b100,b102 >
Free v/f 3 b104
Free v/f 3 b104
Free v/f frequency 4-6 b106,b108,b110 <
Free v/f frequency 1-3 b100,b102,b104 >
Free v/f 4 b106
Free v/f 4 b106
Free v/f frequency 5,6 b108,b110 <
Free v/f frequency 1-4 b100,b102,b104,b106 >
Free v/f 5 b108
Free v/f 5 b108
Free v/f frequency 6 b110 < Free v/f 6 b110
110
Free v/f frequency 1-5 b100,b102,b104,b106,b108 > Free v/f 6 b110
Free electronic thermal frequency 2,3 b017,b019 <
Free electronic thermal
frequency 1 b015
Free electronic thermal frequency 1 b015 >
Free electronic thermal frequency 3 b019 <
Free electronic thermal
frequency 2 b017
120
Free electronic thermal frequency 1,2 b015,b017 >
Free electronic thermal
frequency 3 b019
Warning is cleared when the setting fulfils the above condition.
Date will be changed automatically to the basic code.
(note 1)The jump frequency will be automaically re-written to the lowest jump frequency
(=jump frequency - jump width)