Hitachi SJ300 Welding System User Manual


 
1- 6
Function mode
Code Function name SJ300 Setting range
Initial data
-FE/-FU/-F
Note
C011
Intelligent input 1 a/b
(NO/NC) selection
00(NO)/01(NC) 00
C012
Intelligent input 2 a/b
(NO/NC) selection
00(NO)/01(NC) 00
C013
Intelligent input 3 a/b
(NO/NC) selection
00(NO)/01(NC) 00
C014
Intelligent input 4 a/b
(NO/NC) selection
00(NO)/01(NC) 00
C015
Intelligent input 5 a/b
(NO/NC) selection
00(NO)/01(NC) 00
C016
Intelligent input 6 a/b
(NO/NC) selection
00(NO)/01(NC) 00/01/00
C017
Intelligent input 7a/b
(NO/NC) selection
00(NO)/01(NC) 00
C018
Intelligent input 8 a/b
(NO/NC) selection
00(NO)/01(NC) 00
C019
Input FW a/b (NO/NC)
Selection
00(NO)/01(NC) 00
C021 Intelligent output 11 setting 01
C022 Intelligent output 12 setting 00
C023 Intelligent output 13 setting 03
C024 Intelligent output 14 setting 07
C025 Intelligent output 15 setting 08
C026 Alarm relay output
00(RUN:running)/01(FA1:Frequency arrival type1 signal)/
02(FA2:over setting frequency)/03(OL:Overload advance notice signal)/
04( OD:Output deviation for PID control)/05( AL:Alarm signal)/
06(FA3:Only setting frequency)/07(OTQ:Over-torque signal)/
08( IP:On instantaneous stop)/09(UV:Under voltage)/
10(TRQ:Torque limit)/11(RNT:RUN time over/12(ONT:ON time over)/
13(THM:thermal caution)/19(BRK:Brake release signal)/
20( BER:Brake error signal)/21(ZS:Zero speed detect signal)/
22(DSE:Speed error over signal)/23(POK:Positioning completion signal)
24(FA4:Over frequency 2 signal)/25(FA5:Only setting frequency)/
26(OL2: Overload advance notice signal 2)
(Intelligent output terminal 11-13 or 11-14 becomes AC0-AC2 or AC0-AC3
(Can:Alarm cord output) forcibly when alarm cord output is selected in
C062)
05
C027 FM selection
00(Output frequency)/01(Output current) /02(Output torque)/
03(Digital output frequency)/04(Output voltage)/
05(Input electric power)/06(thermal load rate)/07(LAD frequency)
00
C028 AM selection
00(Output frequency)/01(Output current)/02(Output torque)/
04(Output voltage)/05(Input electric power)/06(thermal load rate)/
07(LAD frequency)
00
C029 AMI selection
00(Output frequency)/01(Output current)/02(Output torque)/
04(Output voltage)/05(Input electric power)/
06(Thermal load rate)/07(LAD frequency)
00
C031 Intelligent output 11 a/b 00(NO)/01(NC) 00
C032 Intelligent output 12 a/b 00(NO)/01(NC) 00
C033
Intelligent output 13 a/b 00(NO)/01(NC) 00
C034
Intelligent output 14 a/b 00(NO)/01(NC) 00
C035
Intelligent output 15 a/b 00(NO)/01(NC) 00
C036
Alarm relay output a/b 00(NO)/01(NC) 01
C040
Overload advance notice
signal output mode
00(On accel. And decel, constant speed)/01(Only constant speed) 01
C041
Overload advance notice
level
0.0-2.0*rated current(A)
Inverter
rated current
C042
Frequency arrival setting for
acceleration.
0.00-99.99/100.0-400.0(Hz) 0.00
C043
Arrival frequency setting for
deceleration.
0.00-99.99/100.0-400.0(Hz) 0.00
C044
PID deviation setting level 0.0-100.0(%) 3.0
C045
Frequency arrival setting for
acceleration 2.
0.00-99.99/100.0-400.0(Hz) 0.00
C046
Arrival frequency setting for
deceleration 2.
0.00-99.99/100.0-400.0(Hz) 0.00
C055
Over torque level setting
(Forward-driving)
0.-200.(%) <0.-180.> 100.
C056
Over torque level setting
(Reverse-regenerating)
0.-200.(%) 100.
C057
Over torque level setting
(Reverse-driving)
0.-200.(%) <0.-180.> 100.
C058
Over torque level setting
(Forward-regenerating)
0.-200.(%) <0.-180.> 100.
C061
Thermal warning level
setting
0.-100.(%) <0.-180.> 80.
C062
Alarm code selection 00(Invalid)/01(3bit)/02(4bit) 00
C063
Zero speed detection level
setting
0.00-99.99/100.(Hz) 0.00
C070
Data command 02(operator)/03(RS485)/04(option1)/05(option2) 02
C071
Communicating transmission
speed
02(loop-back test)
03(2400bps)/04(4800bps)/05(9600bps)/06(19200bps)
04
C072
Communication code 1. -32. 1.
C073
Communication bit 7(7bit)/8(8bit) 7
C074 Communication parity 00(no parity name)/01(even parity)/02(odd parity) 00
C075
Communication stop bit 1(bit)/2(bit) 1
C078
Communication waiting time
0.-1000.(ms) 0.
C081 O adjustment 0.-9999./1000-6553(10000-65530)
Setting on
forwarding
C082 OI adjustment 0.-9999./1000-6553(10000-65530)
Setting on
forwarding
C083 O2 adjustment 0.-9999./1000-6553(10000-65530)
Setting on
forwarding
C085
Thermistor adjustment 0.0 - 1000. 105.0
C086 AM offset adjustment 0.0 - 10.0(V) 0.0
C087 AMI adjustment 0. - 255. 80
C088 AMI offset adjustment 0. - 20.0(mA) 4.0
(Note) < > indicate the setting range of 75 to 150kW
Analog meter setting
Intelligent output terminal setting
Input terminal setting
intelligent
Output terminal state
setting,Output level setting
Communication
function adjustment