OM-2210 Page 11
SECTION 3 − INSTALLATION
3-1. Specifications For Units Connected to a 20 Ampere, 115 Volt Circuit or a 10 Ampere,
230 Volt Circuit
Amperes Input at
Rated Output,
60 Hz, Single-Phase
115 V
230 V
Plasma
Plasma
Gas Flow/
Rated
Cutting
Capacity
Max
Rated Output
115 V 230 V
115 V
KVA/KW
230 V
KVA/KW
Plasma
Gas
Gas Flow/
Pressure
Capacity
at 10 IPM
Max
OCV
21 A at 88 Volts DC At
35% Duty Cycle
25.3 max;
15 eff
12.6 max;
7.5 eff
2.9 KVA
2.2 KW
2.9 KVA
2.2 KW
Air Or
Nitrogen
Only
4.5 CFM
(129 L/min)
At 60 PSI
(414 kPa)
115 VAC
Input: 1/4 in
(6 mm);
230 VAC
Input: 5/16 in
(8 mm)
265 Volts
DC
3-2. Specifications For Units Connected to a 30 Ampere, 115 Volt Circuit or a 15 Ampere,
230 Volt Circuit
If the unit is operated from a 30 ampere, 115 volt circuit or a 15 ampere, 230 volt
circuit, a different input power plug must be installed on the power cord. See
Section 3-9 for instructions.
NOTE
Amperes Input at
Rated Output,
60 Hz, Single-Phase
115 V
230 V
Plasma
Plasma
Gas Flow/
Rated
Cutting
Capacity
Max
Rated Output
115 V 230 V
115 V
KVA/KW
230 V
KVA/KW
Plasma
Gas
Gas Flow/
Pressure
Capacity
at 10 IPM
Max
OCV
27 A at 91 Volts DC At
35% Duty Cycle
33.6 max;
19.9 eff
16.8 max;
9.9 eff
3.8 KVA
3.1 KW
3.8 KVA
3.1 KW
Air Or
4.5 CFM
115 VAC
Input: 1/4 in
21 A at 88 Volts DC At
60% Duty Cycle
25.3 max;
19.6 eff
12.6 max;
9.8 eff
2.9 KVA
2.2 KW
2.9 KVA
2.2 KW
Air Or
Nitrogen
Only
4.5 CFM
(129 L/min)
At 60 PSI
(414 kPa)
Input: 1/4 in
(6 mm);
230 VAC
Input: 5/16 in
265 Volts
DC
17 A at 87 Volts DC At
100% Duty Cycle
20.9 max;
20.9 eff
10.5 max;
10.5 eff
2.4 KVA
1.8 KW
2.4 KVA
1.8 KW
Only
At 60 PSI
(414 kPa)
Input: 5/16 in
(8 mm)
3-3. Specifications For CE Model
Amperes Input at
Rated Output,
50 Hz,
Single-Phase
Plasma
Plasma
Gas Flow/
Max
IP
Rated Output
115 V 230 V
KVA KW
Plasma
Gas
Gas Flow/
Pressure
Max
OCV
IP
Rating
115 VAC Input:
20 A @ 89 Volts DC
(20 A Input Circuit);
25 A @ 89 Volts DC
(30 A Input Circuit);
230 VAC Input:
25 A @ 89 Volts DC;
35% Duty Cycle In All
Cases
26
(0.4*)
17
(0.2*)
115 VAC
Input: 3.1
(0.05*)
230 VAC
Input: 4.0
(0.05*)
115 VAC
Input: 2.4
(0.04*)
230 VAC
Input: 3.1
(0.04*)
Air Or
Nitrogen
Only
4.5 CFM
(129 L/min)
At 60 PSI
(414 kPa)
265 Volts DC 23
*While idling