Hobart Welding Products OM-240 438B Welding System User Manual


 
. A complete Parts List is available at www.HobartWelders.com
OM-240 438 Page 21
! Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
! Also see AWS Safety &
Health Fact Sheet No. 29,
Grounding of Portable And
Vehicle Mounted Welding
Generators.
! Bed liners, shipping skids,
and some running gear insu-
late the welding generator
from the vehicle frame. Al-
ways connect a ground wire
from the generator equip-
ment grounding terminal to
bare metal on the vehicle
frame as shown.
! If unit does not have GFCI re-
ceptacles, use GFCI-pro-
tected extension cord.
1 Equipment Grounding
Terminal (On Front Panel)
2 Grounding Cable (Not
Supplied)
3 Metal Vehicle Frame
Connect cable from equipment
ground terminal to metal vehicle
frame. Use #10 AWG or larger
insulated copper wire.
. Electrically bond generator
frame to vehicle frame by met-
al-to-metal contact.
5
-3. Grounding Generator To Truck Or Trailer Frame
rot_grnd 2008-01 800 652-D
1
3
2
GND/PE