Hobart Welding Products OM-240 438B Welding System User Manual


 
. A complete Parts List is available at wwwHobartWelders.com
OM-240 438 Page 30
SECTION 7 OPERATING AUXILIARY EQUIPMENT
7-1. Standard Receptacles
244 029-A / 281 080-A
! If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.
. Generator power decreases as weld
current increases.
Set Fine Control R1 at 10 for full gen-
erator power.
1 240 V 50 A AC Receptacle RC1
RC1 supplies 60 Hz single-phase power
at weld/power speed. Maximum output is
11 kVA/kW.
2 120 V 20 A AC Duplex Receptacle
RC2
3 120 V 20 A AC Duplex Receptacle
RC3
RC2 and RC3 supply 60 Hz single-phase
power at weld/power speed. Maximum
output from RC2 or RC3 is 2.4 kVA/kW.
4 240 V 50 A AC Receptacle RC5
RC5 supplies 60 Hz single-phase power
at weld/power speed. Maximum output is
11 kVA/kW.
5 Supplementary Protector CB1
CB1 protects receptacles RC1, RC2,
RC3, and RC5 from overload. If CB1
opens, the receptacles do not work. Place
switch in On position to reset.
6 Supplementary Protector CB2
7 Supplementary Protector CB3
CB2 protects RC2 and CB3 protects RC3
from overload. If a supplementary protec-
tor opens, the receptacle does not work.
Combined output of all receptacles limited
to the rating of the generator.
. Press button to reset. If supplementa-
ry protector continues to open, con-
tact Factory Authorized Service
Agent.
Example: If 20 A is drawn from each 120
V duplex receptacle, only 26 A is available
at the 240V receptacle:
2 x (120 V x 20 A) + (240 V x 26 A) = 11.0
kVA/kW