Hobart Welding Products OM-487 Welding System User Manual


 
OM-487 Page 15
4-4. Adding Coolant To Radiator
ST-801 939-C / Ref. ST-187 602-A
Y Stop engine and let cool.
. Check coolant level according
to Section 4-3 before starting
this procedure.
If coolant level is below bottom of
radiator filler neck, add coolant as
follows:
1 Thermostat Housing Plug
Remove thermostat housing plug.
Add coolant to radiator until coolant
is at bottom of filler neck and cool-
ant trickles out of thermostat hous-
ing plug hole. This ensures all air is
purged from the system.
Reinstall plug and radiator cap.
Check coolant level in recovery
tank (see Section 4-3).
Engine coolant is a mixture of water
and ethylene glycol base anti-
freeze. A solution of 50% antifreeze
and 50% water must be used in this
engine. Do not use 100% antifreeze
or severe damage will occur.
Full
Capacity: w/Overflow
Tank 6.9 qt (6.5 L)
Tools Needed:
8 mm
1
4-5. Connecting The Battery
Ref. ST-801 965 / Ref. ST-187 602-A / Ref. S-0756-D
+
3/8, 1/2 in
Y Connect negative ()
cable last.
Tools Needed:
4-6. Connecting To Weld Output Terminals
Y Do not connect to CC and CV
terminals at the same time.
1 Work Weld Output Terminal
2 Stick/TIG (CC) Weld Output
Terminal
3 Wire (CV) Weld Output
Terminal
For MIG welding, connect work
cable to Work terminal and wire
feeder cable to Wire (CV) terminal.
For Stick/TIG welding, connect
work cable to Work terminal and
electrode holder cable to Stick/TIG
(CC) terminal.
321