Ingersoll-Rand IRN75-160K-2S Air Compressor User Manual


 
IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & IRN 250 - 300H - 2S
http://air.irco.com
33
8.0 GENERAL INFORMATION
8.2 INSTALLATION DRAWING−N37/45K−CC & N50/60H−CC − AIR COOLED
KEY
A 11/2” NPT Air discharge (Female) 60Hz units
11/2” BSP Air discharge (Female) 50Hz units
B Ø63mm (2.48”) Electrical inlet
C 0.38“ NPT (Female)
Note: Pipe condensate drain lines separately to an open
drain due to differences in drain pressures.
Use drain lines at least as large as the connection.
Read operations manual and check local regulations
D Cooling airflow
E Exhaust airflow
F Cabinet cooling airflow
G 4 x Ø 13.0mm (0,5”) Compressor should be
bolted to the floor with fourM10 (0.38”) bolts using holes
shown. Seal base tofloor with cork or rubber.
H INTELLISYS Controller
U Right
V Bottom
W Front
X−X Section through X−X
Y Rear view
Z Plan view