8.0 GENERAL INFORMATION
8.2 INSTALLATION DRAWING−N55/75K−CC & N75/100H−CC−WATER COOLED
KEY
A 2” NPT Air discharge (Female) 60Hz units
2” BSP Air discharge (Female) 50Hz units
B Ø63mm (2.48”) Electrical inlet
C 0.38“ NPT (Female)
Note: Pipe condensate drain lines separately to an
open drain due to differences in drain pressures.
Use drain lines at least as large as the connection.
Read operations manual and check local
regulations
D Cooling airflow
E Exhaust airflow
F Cabinet cooling airflow
G 4 x Ø 13.0mm (0,5”)
Compressor should be bolted to the floor with
four M10 (0.38”) bolts using holes shown. Seal
base to floor with cork or rubber.
H INTELLISYS Controller
J 1” NPT Water inlet (Female) 60Hz units
1” BSP Water inlet (Female) 50Hz units
K 1” NPT Water outlet (Female) 60Hz units
1” BSP Water outlet (Female) 50Hz units
U Right
V Bottom
W Front
X−X Section through X−X
Y Rear view
Z Plan view