John Deere TY25862 Battery Charger User Manual


 
Controls and Operation
OURGP12,0000110 –19–02JUN04–3/3
TYB4753 –UN–31AUG04
TY25862 Control Panel
D—Charge Rate Switch
E—Charge Time Switch
NOTE: Battery charger is NOT automatic, and can
overcharge a battery if permitted to operate for
extended periods of time. Monitor the charging
often.
NOTE: Charger may produce a buzzing noise during
charging. This is normal. Continue to charge the
battery. Noise may continue after battery charger
is disconnected from battery.
6. Set charge rate switch (D) to desired Volt/Amp
position. Refer to following Charge Rate Table.
7. Set charge time switch (E) from OFF position to
desired time position. Refer to Charge Rate Table for
time for charge rate selected in previous step.
NOTE: When charge state is not known, start with a timer
setting of one hour or less.
CHARGE RATE/CHARGE TIME
BATTERY SIZE/RATING
(HOURS)*
10 AMP 50 AMP
200-315 CCA 40-60 RC 2.5 - 3 NR
315-550 CCA 60-85 RC 3 - 4 0.6 - 1
550-875 CCA 85-125 RC 4- 5 1 - 1.3
55 MC 4 NR
MARINE/
80 MC 5 NR
DEEP CYCLE
105 MC 6 NR
* - Based on battery at 50% charge.
NR - Not Recommended
CCA - Cold Cranking Amps
RC - Reserve Capacity
MC - Marine Capacity
8. When battery is fully charged, turn charge rate and
charge time switches OFF, disconnect AC cord,
remove clamp from the jumper cable, and then remove
the clamp from the battery terminal.
15-13
091604
PN=28