Liebert gxt2u Welding System User Manual


 
Specifications
32
11.0 SPECIFICATIONS
Model Number GXT2-500RT120 GXT2-700RT120 GXT2-1000RT120
Model Rating 500VA/350W 700VA / 490W 1000VA / 700W
DIMENSIONS - in. (mm)
Unit
W x D x H
3.5 x 21.5 x 17
(87 x 547 x 430)
3.5 x 21.5 x 17
(87 x 547 x 430)
3.5 x 21.5 x 17
(87 x 547 x 430)
Shipping
W x D x H
10.6 x 27.2 x 23
(269 x 691 x 584)
10.6 x 27.2 x 23
(269 x 691 x 584)
10.6 x 27.2 x 23
(269 x 691 x 584)
WEIGHT - lb. (kg)
Unit 48.9 (22.2) 48.9 (22.2) 49.1 (22.3)
Shipping 57.7 (26.2) 57.7 (26.2) 57.9 (26.3)
INPUT AC PARAMETERS
Voltage Range (typical) 120VAC nominal; variable based on output load
100% - 90% loading 80 VAC - 140 VAC 80 VAC / 140 VAC 80 VAC / 140 VAC
90% -70% loading 80 VAC - 140 VAC 80 VAC / 140 VAC 80 VAC / 140 VAC
70% -30% loading 70 VAC - 140 VAC 70 VAC / 140 VAC 70 VAC / 140 VAC
30% - 0% loading 60 VAC - 140 VAC 60 VAC / 140 VAC 60 VAC / 140 VAC
Frequency 40 - 70 Hz; Auto Sensing
Input Power Cord
6 ft. attached
w/ NEMA 5-15 plug
6 ft. attached
w/ NEMA 5-15 plug
10 ft. attached
w/ NEMA 5-15 plug
OUTPUT AC PARAMETERS
Output Receptacles (6) NEMA 5-15R
Voltage 100/110/115/120/127 (user configurable) VAC; ±3%
Frequency 50 Hz or 60 Hz
Waveform Sinewave
Main Mode
Overload
200% for 8 cycles; 130% for 10 seconds with transfer to bypass
BATTERY PARAMETERS
Type Valve-regulated, nonspillable, lead acid
Qty x V x Rating 4 x 12V x 7.0 or 7.2 AH
Battery Mfg / Part # China Storage Battery / CSB 1270 F2
Backup Time See 13.0 - Battery Run Times
Recharge Time 5 hours to 95% capacity after full discharge into 100% load
ENVIRONMENTAL
Operating Temp +32°F to +104°F (0°C to +40°C)
Storage Temp +5°F to +122°F (-15°C to +50°C)
Relative Humidity 0% to 95%, non-condensing
Operating Elevation Up to 10,000 ft. (3000m) at 104°F (40°C) without derating
Storage Elevation 50,000 ft. (15,000m) maximum
Audible Noise
<50 dBA, at 1 meter from the rear
<45 dBA, at 1 meter from the front or sides
AGENCY
Safety UL 1778, c-UL Listed
RFI/EMI FCC Part 15, Subpart B, Class A
Surge Immunity IEEE/ANSI C62.41 Category A & B
Transportation ISTA Procedure 1A
DISCONTINUED
PRODUCT