Lincoln Electric 500 Welder User Manual


 
A-8
INSTALLATION
COMMANDER 500
A-8
CONNECTION OF LINCOLN
ELECTRIC WIRE FEEDERS
Shut off welder before making any electrical connec-
tions.
------------------------------------------------------------------------
CONNECTION OF THE LN-25 TO THE
COMMANDER 500
The LN-25 with or without an external contactor may
be used with the Commander 500. See the appropri-
ate connection diagram in the DIAGRAMS section.
NOTE: The LN-25 (K431) Remote Control Module and
(K432) Remote Cable are not recommended for use
with the Commander 500.
Shut the welder off.
For electrode Positive, connect the electrode cable
from the LN-25 to the + terminal of the welder and
work cable to the - terminal of the welder. For elec-
trode Negative, connect the electrode cable from the
LN-25 to the - terminal of the welder and work
cable to the + terminal of the welder.
Attach the single lead from the front of the LN-25 to
work using the spring clip at the end of the lead. This
is a sense lead to supply current to the wire feeder
motor; it does not carry welding current.
Set the SELECTOR switch to the CV-WIRE posi-
tion.
Set the WELDING TERMINALS switch to WELD
TERMINALS ON
Adjust the ARC CONTROL knob to desired crisp-
ness. Generally, welding is best if the ARC CON-
TROL is set to SOFT for MIG and CRISP for
Innershield. You may however, want to start in the
middle and adjust (as needed) from there.
Set the IDLE switch to the AUTO position. When
not welding, the Commander 500 engine will be at
the low idle speed. If you are using an LN-25 with an
internal contactor, the electrode is not energized until
the gun trigger is closed.
If you are using an LN-25 without an internal contactor,
the electrode will be energized when the Commander
500 is started.
------------------------------------------------------------------------
h. When the gun trigger is closed, the current sensing
circuit will cause the Commander 500 engine to go
to the high idle speed, the wire will begin to feed
and the welding process started. When welding is
stopped, the engine will revert to low idle speed
after approximately 12 seconds unless welding is
resumed.
CONNECTION OF LN-7 OR LN-8 TO THE
COMMANDER 500
Shut the welder off.
Connect the LN-7 or LN-8 per instructions on the
appropriate connection diagram in the DIAGRAMS
section.
Set the WIRE FEEDER VOLTMETER switch to
either + or - as required by the electrode being
used.
Set the SELECTOR switch to the CV-WIRE posi-
tion.
Adjust the ARC CONTROL knob to desired
Crispness. SOFT for MIG and CRISP for Innershield.
Set the WELDING TERMINALS switch to the
REMOTELY CONTROLLED position.
Set the IDLE switch to the HIGH position. When
not welding, the Commander 500 engine will be at
the low idle speed.