Lincoln Electric IM622 Welding System User Manual


 

"##
""##!(

"##"!
The K1534-2 6” silencer can be used on the outlet of
the SF2400 stationary fan to reduce airflow noise lev-
els.
The K1534-2, 6” Air Exhaust Silencer Includes:
• Air Exhaust Silencer, with 6” (160 mm) connections
• Elbow, 90˚, with 6” (160 mm) connections
• (2) Fittings, to fit on the OD of the:
Outlet of the SF2400 Fan
Elbow, 90˚
Air Exhaust Silencer
Install the silencer and the connecting ductwork into
the outlet of the fan. If venting extracted air outside,
apply the supplied ductwork between the fan and
silencer, then use 160 mm (6.3 in.) ductwork or flexi-
ble hose to route the exhausted air outside through a
hole in the wall or roof.
"###
"##'
The Statiflex 200-M Wall-Mounted Filter Unit can be
installed to filter the exhausted air before it is recircu-
lated or exhausted outside. The Air Exhaust Silencer
is unnecessary when a Statiflex 200-M Filter is used.
The K1654-1 Statiflex 200-M Filter Unit Includes:
• Complete Filter Unit, with filter installed and
inlet(s) and outlet(s) sealed
• Reducer, 6”-8”
• 8” Connection hose, 4 ft. long
• (2) 8” Hose Clamps
Fit the small (6” diam.) side of the 6”-8” Reducer over
the outlet of the SF2400 Fan (See A); be sure to slide
the Reducer all the way over the rubber seal. Secure
with three sheet-metal screws through the reducer
into the plastic-molded fan outlet.
Fit one end of the 8” Connection hose (See B) over
the larger side of the 6”-8” Reducer. Secure with one
8” hose clamp.
Mount the Statiflex mounting bracket (Fig. 17A) to the
wall where convenient with the following in mind:
• Access to the filter (for maintenance) is by lifting the
large red cover over the (internal) filter. The easiest
method is to lift the entire filter unit off the mounting
bracket (about 2-4” higher than its mounting height)
and set it down on the floor, then perform any neces-
sary maintenance.
• The 8” connection hose must reach (comfortably)
the inlet of the Statiflex 200-M; the inlet (when mount-
ed) is approximately 10 in. off the left side of the
Statiflex mounting bracket.
• The Statiflex 200-M may be mounted on either side
of the fan, as long as the connection hose reaches
from the outlet of the fan to the inlet of the Statiflex
200-M.
• Recommended mounting height of the Statiflex
mounting bracket is less than 7 ft. from the floor to the
drilled holes. It is recommended to mount the bracket
about 30-36 in. off the outlet of the fan (to the right).
Before lifting the Statiflex 200-M Filter Unit onto the
mounting bracket:
•  Cut the left inlet (or right, depending on which side
of the fan it is to be mounted) open (See C). A hack-
saw or multi-purpose power saw may be used.
• Unscrew the thumb nut and remove the filter cover
(See D). Cut one or both outlet openings (See E)
open. Replace the filter cover and thumb nut.
Lift the Statiflex 200-M onto the mounting bracket;
refer to Figure 18. The installation may be made per-
manent by running (2) self-tapping screws (FIg. 18E)
in through the plastic base against the wall bracket.
A
11.4"
(290 mm)
A
11.4"
(290 mm)
20
A
D
B
C
E

C 
A
D
B
C
E

C
A
D
E
CB

C 
A
D
E
CB

C
20