Miller Electric 652 Welder User Manual


 
. A complete Parts List is available at www.MillerWelds.com
OM-278 Page 19
4-15. Connecting Remote Control
Ref. 800 166-D
! Turn off power before con-
necting a remote control.
1 Remote 14 Receptacle RC8
Connect remote control to RC8.
OR
OR
AJ
B
K
I
C
L
NH
D
M
G
E
F
1
4-16. Electrical Service Guide
60 Hz Models 50 Hz Models
Input Voltage 230 460 575 380 400 440 520
Input Amperes At Rated Output 126 63 50.4 77 73 66 54
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay
2
150 70 60 90 90 80 60
Normal Operating 3 200 90 80 125 110 100 80
Min Input Conductor Size In AWG
4
1 6 6 4 4 4 6
Max Recommended Input Conductor Length In Feet (Me-
ters)
208
(64)
328
(100)
513
(156)
335
(102)
371
(113)
449
(137)
419
(128)
Min Grounding Conductor Size In AWG
4
6 8 8 6 6 8 8
Reference: 2005 National Electrical Code (NEC)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.