Miller Electric Auto Axcess 675 Welder User Manual


 
OM-201 540 Page 13
3-5. Selecting A Location
loc_2 3/96 -Ref. 802 913-B
! Do not stack units. Beware of
tipping.
1 Lifting Forks
Use lifting forks to move unit.
Extend forks beyond opposite side
of unit.
2 Hand Cart
Use cart or similar device to move
unit.
3 Rating Label
Use rating label to determine input
power needs.
4 Line Disconnect Device
Locate unit near correct input
power supply.
Movement
2
Location
4
18 in
(460 mm)
18 in
(460 mm)
3
Tipping
1
OR
! Do not move or operate
unit where it could tip.
! Special installation may be required where gasoline or volatile
liquids are present − see NEC Article 511 or CEC Section 20.
Ref. 802 913-B / Ref. 801 915-A
. The proper interface kit must
be installed in the welding pow-
er source/interface unit to allow
it to be connected to the robot.
1 Robot (Will Vary According To
Application)
2 Motor/Drive Assembly
3 Gas Cylinder
4 Gas Hose
5 Robot Control
6 Robot Input/Output Cable
7 Gas And Motor Control Cable
8 Welding Power
Source/Interface Unit
9 Negative (−) Weld Cable
10 Workpiece
11 Voltage Sensing Lead
(Optional)
. Positive (+) voltage sensing
lead is contained in the motor
cable.
12 Positive (+) Weld Cable
3-6. Connection Diagram
1
2 3
4
5
7
6
8
9
10
11
12