Miller Electric Big Blue 602DR Welding System User Manual


 
OM-495 Page 30
Return To Table Of Contents
5-9. Engine Prestart Checks
. Check all engine fluids daily.
Engine must be cold and on a level surface.
Unit is shipped with 20W break-in oil. The
Automatic shutdown system stops engine if
oil pressure is too low or coolant tempera-
ture is too high.
. This unit has a low oil pressure shut-
down switch. However, some condi-
tions may cause engine damage before
the engine shuts down. Check oil level
often and do not use the oil pressure
shutdown system to monitor oil level.
Follow run-in procedure in engine manual.
If unburned fuel and oil collect in exhaust
pipe during run-in, see Section 13.
Fuel
Y Do not use gasoline. Gasoline will
damage engine.
Add fresh diesel fuel before starting to pre-
vent air from entering the fuel system (see
engine maintenance label for fuel specifica-
tions). Leave filler neck empty to allow room
for expansion.
Do not run out of fuel or air may enter fuel
system and cause starting problems. See
engine manual to bleed air from fuel system.
Oil
After fueling, check oil with unit on level sur-
face. If oil is not up to full mark on dipstick,
add oil (see maintenance label).
. To improve cold weather starting:
Use optional Starting Aid switch (see
Section 6-1 or 7-1).
Keep battery in good condition. Store
battery in warm area.
Use fuel formulated for cold weather
(diesel fuel can gel in cold weather).
Contact local fuel supplier for fuel in-
formation.
Use correct grade oil for cold weather
(see Section 9-2 or 10-2).
Full
Ref. 802 313-A / 802 398-A
Diesel
Full
Diesel
Full
Deutz F4L2011 Engine
Deutz F3L912 Engine
Full