Miller Electric Big Blue 602DR Welding System User Manual


 
OM-495 Page 41
Return To Table Of Contents
7-4. Remote Voltage/Amperage Control On CC/CV Models (Optional)
1 Remote 14 Receptacle RC14
Connect optional remote control to
RC14 (see Section 5-13).
0774 / Ref. 192 895-A / 802 311-A
Example: Combination Remote Amperage Control (Stick)
In Example:
Process = Stick (Using Remote On/Off)
Range = 125 to 320 A DC
Min = 125 A DC
Max = 320 A DC
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range Control Not
Used In Remote
Stick Mode
Max (320 A DC)
Min (125 A DC)
Set Remote
Process
Example: Combination Remote Amperage Control (TIG)
In Example:
Process = TIG (Using Remote On/Off)
Range = 40 to 200 A DC
Percentage Of Range = 50%
Min = 40 A DC
Max = About 120 A DC (50% of 40 to 200)
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range Set Control
Max (120 A DC)
Min (40 A DC)
Set Remote
Process
1