Miller Electric Big Blue 602DR Welding System User Manual


 
OM-495 Page 54
Return To Table Of Contents
SECTION 10 MAINTENANCE (DEUTZ F3L912POWERED UNITS)
Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.
Note
10-1. Routine Maintenance (Deutz F3L912-Powered Units)
Recycle
engine
fluids.
Y Stop engine before maintaining.
. See Engine Manual and Maintenance Label for
important start-up, service, and storage informa-
tion. Service engine more frequently if used in se-
vere conditions.
* To be done by Factory Authorized Service Agent.
Every 8 h
Wipe Up
Spills.
Check Fluid
Levels. See
Section 5-9.
Drain Water
From Fuel
System. See
Section 10-7.
FUEL
WATER
Every 50 h
Clean Air Filter.
See Section
10-3.
Clean And
Tighten Weld
Terminals.
Every 100 h
Clean
Cooling
System.
Clean And
Tighten
Battery
Connections.
Check air cleaner
hoses for cracks
and loose clamps.
Every 250 h
Replace
Unreadable
Labels.
1/2 in.
(13 mm)
Check
Belt
Tension.
Check And
Clean Spark
Arrestor. See
Section 10-4.