Miller Electric Maxstar 200 STR Welder User Manual


 
OM-2233 Page 12
SECTION 4 INSTALLATION
4-1. Specifications
Input Power
Rated Output
Welding
Amperage
Max.
Open-Circuit
Amperes Input At Rated Output, 50/60Hz
KVA
KW
I
nput
P
ower
R
ate
d O
utput
Amperage
Range
O
pen-
C
ircuit
Voltage
115 230 400 460
KVA
KW
Three-Phase
Stick Process
150 A @ 26 VDC,
60% Duty Cycle
1 200
80
9-14
-
13.1
0.16*
7.4
0.24*
6.4
0.25*
5.2
0.06*
5.0
0.03*
Three-Phase
TIG Process
175 A @ 17 VDC,
60% Duty Cycle
1 200
80
9-14
-
10.5
0.16*
6.0
0.24*
5.2
0.25*
4.2
0.06*
4.0
0.03*
Three-Phase
Stick Process
200 A @ 28 VDC,
30% Duty Cycle
1 200
80
9-14
18.4
0.16*
10.3
0.24*
8.9
0.25*
7.3
0.06*
7.0
0.03*
Three-Phase
TIG Process
200 A @ 18 VDC,
40% Duty Cycle
1 200
80
9-14
12.7
0.16*
7.2
0.24*
6.2
0.25*
5.1
0.06*
4.9
0.03*
Single-Phase
Stick Process
150 A @ 26 VDC,
60% Duty Cycle
1 200
80
9-14
-
21.7
0.23*
-
10.6
.25*
5.0
0.05*
5.0
0.02*
Single-Phase
TIG Process
175 A @ 17 VDC,
60% Duty Cycle
1 200
80
9-14
-
17.4
0.23*
-
8.5
.25*
4.0
0.05*
4.0
0.02*
Single-Phase
Stick Process
125 A @ 25 VDC,
50% Duty Cycle
1 200
80
9-14
34.1
0.42*
-
- -
4.0
0.05*
3.8
0.03*
Single-Phase
TIG Process
150 A @ 16 VDC,
70% Duty Cycle
1 200
80
9-14
29.7
0.42*
-
- -
3.4
0.05*
3.4
0.03*
Single-Phase
Stick Process
100 A @ 24 VDC,
80% Duty Cycle
1 200
80
9-14
28.1
0.42*
- - -
3.2
0.05*
3.2
0.03*
Single-Phase
TIG Process
125 A @ 15 VDC,
100% Duty Cycle
1 200
80
9-14
23.0
0.42*
- - -
2.6
0.05*
2.6
0.03*
*While idling
Low open-circuit voltage while in Lift-Arct on all models, and Stick on models with stock numbers 907 036 and 907 037.
Normal open-circuit voltage (80 volts) is present while in the Stick process for models with stock number 907 220.
NOTE: Duty cycle limitations on units with 115 volt input power are due to the input power cord supplied with the unit.
NOTE: This unit is equipped with Auto-Linet. The Auto-Line circuitry automatically connects to 120460 VAC, single- or three-phase power without
removing the cover to relink the power source.