OM-1500-19 Page 27
Trouble Remedy
Information on display board is not accu-
Have Factory Authorized Service Agent check Control board PC1.
Information on display board is not accu
rate.
yg
Check transducer HD1 and connections, and replace if necessary.
Display on display board does not light.
Have Factory Authorized Service Agent check Control board PC1.
Replace display board.
Segments on the display board are
missing.
Replace display board.
6-4. Diagnostics
Error Indicators
Shown On Display RED LED on Motor Board PC1 Error
HLP 11 1 Blink Communication Error
HLP 14 4 Blinks
(Constant Blinking)
Motor
Overload Error
HLP 15 3 Blinks Bus Bar
Overheat Error
Error Indications
Error conditions are indicated by a “HLP” message on the display, or by the blinking of the Red LED on Motor
Board PC1. To view the Red LED, turn Off power source, remove shroud, and turn power source On. The Red
LED blinks in a 2.5 second cycle. The number of blinks in this period indicates the type of error. If an error condi-
tion does not exist on the motor board, the Red LED is on steady.
Communication Error
The communication error occurs 2.5 seconds after a loss of communication between the motor board and the
meter board. The user may continue to weld with this error. The error may be cleared by turning power Off, wait-
ing a minimum of two seconds, and turning power On.
Motor Overload Error
The motor overload error can indicate that the motor has been drawing too much current for too long, To remedy
this, reduce the wire feed speed or the wire feeder torque load/duty cycle. The error may be cleared by turning
power Off, waiting a minimum of two seconds, and turning power On.
Bus Bar Overheat Error
The bus bar overheat error can be caused by the arc drawing too much current for too long. To remedy this, re-