Multiquip HPHA46411H Power Screwdriver User Manual


 
PAGE 20 — HPLA/HPHA-SERIES 46" WALK-BEHIND TROWEL— OPERATION AND PARTS MANUAL — REV. #6 (07/06/10)
Handle Height Adjustment
If handle height adjustment is desired, a handle wedge kit can be
purchased for your trowel by ordering P/N 2576 from your Multiquip
dealer. These wedges are placed between the handle and the
gearbox to adjust the operating height of the handle. This kit
comes complete with wedges, new bolts and installation
instructions. This will move your operating handle position up or
down approximately 3” (76mm).
HPLA/HPHA-SERIES 46" TROWEL — ASSEMBLY AND INSTALLATION
Safety Stop Switch Wire
Locate the
safety stop switch wire
protruding from the handle
tube (Figure10) and connect it to the
tail wire
on the engine.
Test the safety stop switch to insure proper operation.
Figure 10. Engine Safety Stop Wire Connection
Figure 11. "No Pitch" Position (Standard)
Figure 12. "No Pitch" Position (Quick-Pitch™)
1. Expose the pitch cable to maximum by adjusting the handle
pitch to the "no pitch" position. On the standard model turn
the pitch control counter-clockwise, (Figure 11). On the
Quick-Pitch™ model, pivot the pitch handle forward or no
pitch, (Figure 12).
7. These are general instructions. Installation of the throttle
cable may vary for different engine configurations. Please
look for more detailed instructions inside the box containing
the handle. These more detailed instructions should provide
adequate guidance for installing.
4. Tighten cable clamp screw and swivel stop screw.
5. After the cable has been installed on the engine, adjust
and tighten operator position of the handle to lock the
throttle cable at the proper length.
6. Adjust cable tension loosening the lock nut on the throttle
cable receiver (Figure 9), loosening or tightening the
adjuster nut below it, then retightening the lock nut.
Pitch Cable Installation
Figure 9. Throttle Adjust