Oneida Air Systems 10 HP Dust Collector User Manual


 
X. Accessories
O.A.S. 2007
c
10 HP Pulley Drive Owners Manual
Dust Bin Options - (Must Order Custom Cyclone Mounting Stand.)
2. Hoppers -
Large capacity hoppers from .5 cu. yd. to 3 cu. yd.
3/16 reinforcing angle for added support - 3/16 plate body is 100%
continuously MIG welded on inside - 3/8 rear cross brace angle (not 3/16)
- three 3 base channel - All angles are structural not formed.
3. Air Locks -
Rotary air locks provide an
alternative to an air tight dust bin
for larger volume capacity and
less maintenance.
Example - A 10 air lock will drop
1.85 cu. ft. / rev. of material.
1. Multiple Drums -
Custom order the System Mounting Stand for multiple drums or
hoppers. Stand widths will vary depending on dust container.
Magnetic Motor Starters - The 10 and 15hp pulley drive dust collectors
do not come wired or with an on/off switch. Because of the voltage
and amperage requirements of the system, an industrial switch must
be used.
OAS offers Square D Full Voltage Non-Reversing across the Line
Starters, Nema Type 1 Enclosure with Start/Stop in cover, and class
10 overload. Industrial switches can also be purchased through your
local electrician. Due to varying electrical codes, OAS cannot specify
exact wiring requirements. When wiring the collector you should
always hire a licensed electrician.
Bin Level Monitor - Provides level sensing for dry bulk solids. The monitor
operates by using a 1 rpm synchronous motor to rotate a paddle.
When paddle rotation is impeded by material surrounding it, the motor
is de-energized and triggers a SPDT snap switch. The snap switch can
be used in conjunction with a motor starter to turn equipment off or provide
alarm functions.
15
Angle Iron Stands
STZ350055 - Angle Iron Cyclone Stand
STZ990000 -Plenum Stand
4. Cone w/ Clean Out -
Optional cone with clean
out plate for use with
airlocks..