Panasonic FP2 Welding System User Manual


 
Xxxxx Xxxxxxxx
Xxxxx Xxxxxxxx
21
Specifications
FP2/FP2SH
ET-LAN units
Multi-communication units
Performance Specification
Transmission specifications for communication interface
16
Start-stop synchronization
RS232C RS485
Note 1: The protocol can be downloaded from: www.panasonic-electric-works.com
Specifications
Item
Item 100BASE-TX
Item
FP2-MW
W mode
Token bus
Base band
500kbit/s
500kbit/s
500kbit/s, 250kbit/s
W2 mode
1)
F mode
Polling
Item
VE mode (PLC link) FL-net mode
Mode
Communication method
Transmission method
Transmission speed
Transmission
distance
Number of
connectable stations
Transmission error check
Synchronization
Interface
Transmission line
RAS function
Extendable to 800m
250kbits/s: 1200m max.
500kbits/s: 800m max.
Extendable to 800m
32 stations max.
Twisted-pair cable
Hardware self-diagnosis function
Twisted-pair cables
or VCTF cables
Extendable to 700m
CRC (cyclic redundancy check) system
Start-stop synchronization
RS485 compatible
S-LINK units
FP2-SL2
1
128 points max.
CPU unit with S-LINK ports
FP2-C1SL
2
128 points max. × 2
Item
Number of channels
Number of I/O
points
Rated power
supply voltage
Power
consumption
Transmission method
Synchronization
Transmission protocol
Transmission speed
Transmission distance
FAN-OUT
Connection method
* For FP2SH (Cannot be used for FP2)
1)
note 2) note 2)
note 3)
1)
1)
1)
2)
2)
10BASE5 : 500m
(
2500m)
10BASE-T : 100m
(
500m)
FL-net [FA link protocol (UDP/IP)]
MEWTOCOL
Communication
interface
Communication speed
Cycle time
example
Cable length
Communication protocol
Link
communication
specifications
Message communication
specifications
Number of nodes
Other functions
Ethernet
10BASE5/10BASE-T
10Mbit/s
50ms/32 units
(2048 points/2048 words)
Link relay
8192 points/unit
Link register
8192 words/unit
2048 bytes max.
(Compatible with MEWTOCOL)
99 units max.
Data transfer
Remote programming
Multilevel link communications
1024 bytes max.
(Not compatible with MEWTOCOL)
254 units max.
Interconnection with other
companies' units
Communication
block used
Interface
Communication
method
Synchronization
Transmission line
Transmission distance
Transmission speed
(To be set in the system register)
Transmission code
Transmission format
(To be set in the system register)
Number of stations
PLC link capacity
COM1
(upper channel)
COM2
(lower channel)
Number of attachable units
Supported versions
General-purpose serial communications
Computer link
(Panasonic open protocol "MEWTOCOL" should be used.)
1:1 communications 1:N communications 1:1 communications 1:N communications
FP2-CB232
FP2-CB422
RS232C RS422
Full duplex
FP2-CB232
FP2-CB422
RS232C RS422
Full duplex
FP2-CB232
FP2-CB422
Three-core or
five-core shielded wire
15m Length: 1200m max.
300 to 230,400bps
Twisted-pair cable
or VCTF
Length: 1200m max.
300 to 230,400bps
(19,200 bps when our C-NET adapter is connected)
99 stations max.
(32 stations max. when our C-NET adapter is connected)
99 stations max.
(32 stations max. when our C-NET adapter is connected)
16 stations max.
Link relay: 1024 points
Link register: 128 words
Three-core or
five-core shielded wire
15m Length: 1200m max.
300 to 230,400bps
Twisted-pair cable
or VCTF
Length: 1200m max.
300 to 230,400bps
(19,200 bps when our C-NET adapter is connected)
FP2-CB485
RS485
Two-wire half duplex
FP2-CB485
RS485
Two-wire half duplex
ASCII, JIS7, JIS8, and binary
Start code: With STX / Without STX
End code: CR/CR+LF/Time setting/ETX
Data length: 7 bits/8 bits
Parity: 0/Invalid/Valid (Odd/Even)
Stop bit: 1 bit/2 bits
23 units max. (including 8 units for the computer link and 2 channels for the PLC link)
CPU unit (both FP2 and FP2SH): Ver. 1.4 or later, FPWIN GR: Ver. 2.4 or later, FPWIN PRO: Ver. 5.1 or later
ASCII, JIS7, JIS8
PLC link function
Twisted-pair cable
or VCTF
1200m (RS485) 15m (RS232C)
115,200bps
Token passing
(Floating master)
1 master +
32 slave stations max.
Note 1: When the unit is used in W2 mode, it must be set by user programs.
The number of input and output points for each channel can be selected by the switch in the unit body
Input: 0/32/64/96/128 points Output: 0/32/64/96/128 points
+24VDC ±10% Maximum allowable ripples (P-P): ±10%
(S-LINK terminal block IN-24VDC 1.6 A or less)
[Current consumption of the S-LINK controller (incl. D-G line current
consumption)] +24VDC 1.6A or less
[Maximum allowable current supply (Supply to the S-LINK and I/O
devices through the 24V - 0V line)] +24VDC 5A (Fuse: 5A or less)
Bi-directional time division multiplex transmission
Bit/Frame synchronization
S-LINK protocol
28.5kbit/s
Main signal line: Extendable to 200m (max. 400m when a booster is used)
320
T-branch multi-drop wiring or standard multi-drop wiring
[+24, 0V, D-G (with a function of D-G short-circuit protection)]
Notes: 1) Refer to the "Power Capacity Determination" section of SUNX Limited's S-LINK Design
Manual for details of the current consumption.
2) Refer to SUNX Limited's S-LINK Design Manual for the booster and FAN-OUT.
100Mbit/s
Base band
100m
205m (2 segments)
Category 5 UTP cable
100BASE-T
10Mbit/s
Base band
100m
500m (5 segments)
Category 3, 4 and 5 UTP cable
100BASE5
10Mbit/s
Base band
500m
2500m (5 segments)
Transceiver cable
50m
100 nodes/segment
Integer multiples of 2.5m
A
A
A
A
A
A
A
A
A
N/A
A: Available
N/A: Not available
* The lengths in parentheses are
available when a repeater is used.
Notes 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.
2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite
core may be necessary in some cases, depending on the usage environment. Also, if the hub is
positioned close to a control board, we recommend using it at a distance of 10m or less.
3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite
core may be necessary in some cases, depending on the usage environment. Also, if the transceiver is
positioned close to a control board, we recommend using it at a distance of 5m or less.
Communications function
Number of communication connections
Transparent
communications buffer
Transmit
Receive
- MEWTOCOL-COM: computer link function (max. 2KB)
- MEWTOCOL-DAT: data transfer (max. 1020 words)
- Transparent communication
8 connections max.
Factory setting: 1k words/connection x 3
Factory setting: 1k words/connection x 3
Transmission speed
Transmission method
Max. segment length
Max. distance between nodes
Communication cable or connection
Max. transceiver cable
length
Max. number of nodes
Node spacing
Performance Specification
Transmission specifications for communication interface
SpecificationsItem
Item 100BASE-TX
1)
note 2) note 2)
note 3)
1)
100Mbit/s
Base band
100m
205m (2 segments)
Category 5 UTP cable
100BASE-T
10Mbit/s
Base band
100m
500m (5 segments)
Category 3, 4 and 5 UTP cable
100BASE5
10Mbit/s
Base band
500m
2500m (5 segments)
Transceiver cable
50m
100 nodes/segment
Integer multiples of 2.5m
Notes: 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.
2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite core may be necessary in some
cases, depending on the usage environment. Also, if the hub is positioned close to a control board, we recommend using it at a distance
of 10m or less.
3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite core may be necessary in some
cases, depending on the usage environment. Also, if the transceiver is positioned close to a control board, we recommend using it at a
distance of 5m or less.
Communications function
Number of communication connections
Transparent
communications buffer
Transmit
Receive
- MEWTOCOL-COM: computer link function (max. 2KB)
- MEWTOCOL-DAT: data transfer (max. 1020 words)
- Transparent communication
8 connections max.
Factory setting: 1k words/connection x 3
Factory setting: 1k words/connection x 3
Transmission speed
Transmission method
Max. segment length
Max. distance between nodes
Communication cable or connection
Max. transceiver cable
length
Max. number of nodes
Node spacing
FP2/FP2SH
Specifications
08/2007