14
CHECKING THE SAFETY VALVE
See Figure 12.
DANGER:
Do not attempt to tamper with the safety valve.
Anything loosened from this device could fly up
and hit you. Failure to heed this warning could
result in death or serious personal injury.
The safety valve will automatically release air if the air tank
pressure exceeds the preset maximum. The valve should
be checked before each day of use by pulling the ring by
hand.
Turn the air compressor on and allow the tanks to fill. The
compressor will shut off when the pressure reaches the
preset maximum.
Turn the air compressor off.
Pull the ring on the safety valve to release air for three to
five seconds.
Release the ring. Air must immediately stop escaping
when the ring is released. Any continued loss of air after
releasing the safety valve ring indicates a problem with
the safety valve. Discontinue use and seek service before
continued use of the air compressor.
OPERATION
WARNING:
If air leaks after the ring has been released, or
if the valve is stuck and cannot be actuated by
the ring. Do not use the air compressor until
the safety valve has been replaced. Use of the
air compressor in this condition could result in
serious personal injury.
Fig. 12
5 Gallon
18,8 Litre
18,7 Litro
4.4 SCFM @ 90PSI
0,12 m /Min @ 621 kPa
0,12 m /Min @ 6,21 bar
145 Max PSI
999 KpA
9,99 bar
3
3
1
2
MINI WHEELBARROW COMPRESSOR
OIL LUBE PUMP
-
POMPE A HULE - BOMBA CON LUBRICACION DE ACIETE
ON
OFF
O
I
SAFETY VALVE
RING
TO RELEASE AIR
Fig. 13
RESET
BUTTON
RESET BUTTON
See Figure 13.
When amperage into the air compressor exceeds the
specified amperage, the air compressor will automatically
shut off.
To reset the air compressor:
Turn the air compressor off.
Unplug the air compressor for 30 minutes.
NOTE: If the overload protector is actuated, the motor
must be allowed to cool down for 30 minutes before
manual resetting.
Press the reset button.
Plug the air compressor into an approved outlet.
Turn the air compressor on.