RIDGID OL50145MW Air Compressor User Manual


 
16
ON
OFF
O
I
ON
MAINTENANCE
Fig. 15
DRAIN PLUG
OIL FILL HOLE
COLLECT USED OIL IN A
SUITABLE CONTAINER
CHANGING THE OIL
See Figure 15.
Replace the oil after the first 100 hours of operation and
every 100 hours following the first oil change.
Place a suitable container underneath the drain to collect
used oil.
Remove the drain plug with a 8 mm socket or wrench.
When the used oil has drained, reinstall the drain plug
and tighten with the wrench.
Remove the dipstick.
To refill, use a funnel to pour oil into the fill hole. Refill only
with synthetic oil SAE 5W50.
NOTE: Avoid refilling with too much oil. Ensure that the
level of the oil does not exceed the maximum reference
level on the dipstick. The recommended amount of oil for
refilling is 7.2 oz. (204 g).
Reinsert the dipstick securely into the oil fill hole.
DIPSTICK